NY Property Records

262 Clinton Avenue
Brooklyn · Kings County · 11205

02 · Walk-Up AptsLast sold May 1998 · click to view deed ↗
Owner of record
OwnerJohnson, Cameron
Assessment · 2025 roll
Land assessed$3,600
Total assessed$1,554,750
Est. annual tax$27,346 (2027, excl. special districts)
Building
StyleFive to Six Families
Year built1878
Living area5,000 sq ft
Lot
Size0.04 acres (GIS)
Frontage × depth20 × 90 ft
Lot sq ft1,823
Zoning
DistrictR6B
FAR2.74 built · 2.0 max residential · 2.0 max facility
Zoning map16c
Recorded documents · 5
DEED Oct 29, 1998
grantor/seller Johnson, Cameron; Johnson, Thelma
grantee/buyer Johnson, Cameron; Johnson, Thelma
View on ACRIS ↗
SATISFACTION OF MORTGAGE May 29, 1990
mortgager/borrower Johnson, Cameron; Johnson, Thelma
mortgagee/lender Stabile, Mary
View on ACRIS ↗
LANDMARK DESIGNATION Jul 18, 1983
party 1 Landmarks Preserv Com Ny
party 2 Notice Of Designation
View on ACRIS ↗
Show all 5
DEED Nov 9, 1977
grantor/seller Stavile Mary
grantee/buyer Johnson Cameron; Johnson Thelma
View on ACRIS ↗
MORTGAGE Nov 9, 1977
mortgagor/borrower Johnson Cameron; Johnson Thelma
mortgagee/lender Satbile Mary
View on ACRIS ↗
DOB complaints — total 9 · open 0 · closed 9
Work contrary to stop-work order Closed Nov 3, 2023
Complaint 3933675
View on BIS ↗
Sidewalk shed/scaffold – none/inadequate/defective Closed Nov 3, 2023
Complaint 3933679
View on BIS ↗
Work contrary to stop-work order Closed Oct 25, 2023
Complaint 3932458
View on BIS ↗
Show all 9
Work contrary to stop-work order Closed Oct 24, 2023
Complaint 3932317
View on BIS ↗
Sidewalk shed/scaffold – none/inadequate/defective Closed Oct 23, 2023
Complaint 3932223
View on BIS ↗
Category 7J Closed Oct 23, 2023
Complaint 3932251
View on BIS ↗
Category 7J Closed Oct 23, 2023
Complaint 3932206
View on BIS ↗
Category 7J Closed Oct 13, 2023
Complaint 3931013
View on BIS ↗
Egress – locked/blocked/improper/none Closed Apr 29, 2023
Complaint 3902935
View on BIS ↗
HPD violations — total 203 · open 36 · closed 167
C · Immediately hazardous Open Aug 3, 2026
HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 4, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD ↗
C · Immediately hazardous Open Aug 3, 2026
HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 4, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD ↗
B · Hazardous Open Aug 3, 2026
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT EAST WALL IN THE BATHROOM LOCATED AT APT 4, 4th STORY, 1st
HPD ↗
Show all 203
B · Hazardous Open Aug 3, 2026
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND NORTH WALL IN THE 1st ROOM FROM EAST AT NORTH L
HPD ↗
B · Hazardous Open Aug 3, 2026
§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK ACTIVE WATER LEAK AT CEILING IN THE 1st ROOM FROM EAST AT NORTH LOCATED A
HPD ↗
B · Hazardous Open Aug 3, 2026
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT EAST AND SOUTH WALL IN THE 1st ROOM FROM EAST AT SOUTH LOCA
HPD ↗
B · Hazardous Open Aug 3, 2026
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT SOUTH AND WEST WALLS IN THE 2nd ROOM FROM EAST AT SOUTH LOC
HPD ↗
A · Non-hazardous Open Jun 19, 2026
§ 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLL
HPD ↗
A · Non-hazardous Open Jun 19, 2026
§ 27-2049 ADM CODE POST AND MAINTAIN A STREET NUMBER ON THE FRONT OF THE DWELLING PLAINLY VISIBLE FROM THE SIDEWALK.
HPD ↗
B · Hazardous Closed Mar 2, 2026
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT NORTH WALL IN THE KITCHEN LOCATED AT APT 5R, 4th STORY
HPD ↗
B · Hazardous Closed Mar 2, 2026
§ 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK ABOVE CEILING IN THE 2nd ROOM FROM EAST AT SOUTH LOCATED AT APT 5R, 4th STORY
HPD ↗
B · Hazardous Closed Mar 2, 2026
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 2nd ROOM FROM EAST AT SOUTH LOCATED AT APT 5
HPD ↗
I · Order to correct Closed Nov 18, 2025
§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PEN
HPD ↗
C · Immediately hazardous Open Jun 17, 2025
HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 4, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD ↗
B · Hazardous Open Jun 17, 2025
§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT EAST WALL IN THE BATHROOM LOCATED AT APT 4, 4th STORY, 1st APARTMENT F
HPD ↗
B · Hazardous Closed Jun 17, 2025
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE EAST WALL IN THE BATHROOM LOCATED AT APT 4, 4th STORY, 1st
HPD ↗
A · Non-hazardous Open Jun 17, 2025
§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES IN THE 1st ROOM FROM EAST AT SOUTH, THE BATH
HPD ↗
A · Non-hazardous Closed Jun 9, 2025
(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.G
HPD ↗
C · Immediately hazardous Closed Apr 14, 2025
567 (C) § 27-2017, 27-2017.1, 27-2017.4, 27-2017.5, 27-2017.8, 27-2019, 27-2021 HMC: ABATE THE NUISANCE CONSISTING OF EVIDENCE OF RATS AND ALL UNDERLYING CAUSES
HPD ↗
B · Hazardous Closed Feb 16, 2025
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOODEN FLOOR IN THE 3rd ROOM FROM EAST AT SOUTH LOCATED AT APT 4, 3rd STORY, 1s
HPD ↗
C · Immediately hazardous Open Feb 16, 2025
HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 4, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD ↗
C · Immediately hazardous Closed Feb 16, 2025
§ 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTI
HPD ↗
C · Immediately hazardous Closed Feb 16, 2025
§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF NAILS PROTRUDING FROM WOOD FLOOR IN THE FOYER LOCATED AT APT 4, 3rd STORY, 1st APARTMENT FROM
HPD ↗
I · Order to correct Closed Nov 25, 2024
§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PEN
HPD ↗
B · Hazardous Closed Aug 9, 2024
§ 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF MULTIPLE BICYCLES AT FRONT AREAWAY, 1st STORY
HPD ↗
A · Non-hazardous Closed Aug 9, 2024
§ 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWE
HPD ↗
A · Non-hazardous Closed Aug 9, 2024
§ 27-2048 ADM CODE PAINT OR POST A SIGN INDICATING FLOORS AT ALL STORIES AT PUBLIC HALL
HPD ↗
C · Immediately hazardous Closed Dec 14, 2023
§ 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE KITCHEN LOCATED AT APT 4, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD ↗
C · Immediately hazardous Closed Dec 14, 2023
§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM LOCKED AT CELLAR AT BOILER ROOM
HPD ↗
B · Hazardous Closed Oct 24, 2023
§ 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE WATER SUPPLY PIPE AT WATER CLOSET IN THE BATHROOM LOCATED AT APT APT4, 4th STORY, 1st APARTMENT FROM NORTH
HPD ↗
C · Immediately hazardous Closed Oct 24, 2023
HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT APT4, 4th STORY, 1st APARTMENT FROM NORTH AT EAST
HPD ↗
C · Immediately hazardous Closed Oct 24, 2023
HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT APT4, 4th STORY, 1st APARTMENT FROM NORTH AT EAST
HPD ↗
B · Hazardous Closed Oct 24, 2023
§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE INTERCOM SYSTEM AT WEST WALL IN THE PRIVATE HALLWAY LOCATED AT APT APT4, 4th STORY, 1st APARTM
HPD ↗
C · Immediately hazardous Closed Oct 24, 2023
§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE BROKEN GLASS AT BUILDING ENTRANCE DOOR AT PUBLIC HALL, 1st STORY
HPD ↗
A · Non-hazardous Closed Oct 24, 2023
§ 27-2022 ADM CODE POST A SIGN INDICATING HOURS OF COLLECTION AND METHOD OF COLLECTION OF WASTE MATERIAL WHERE DUMBWAITER SERVICE IS NOT PROVIDED. AT PUBLIC HAL
HPD ↗
A · Non-hazardous Closed Oct 24, 2023
§ 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE B
HPD ↗
B · Hazardous Closed Oct 24, 2023
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDENT MATERIAL AT WEST WALL AT PUBLIC HALL, 1st STORY
HPD ↗
A · Non-hazardous Closed Oct 24, 2023
§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX 20 SQF AT WEST WALL AT PUBLIC HALL, 1st STORY
HPD ↗
A · Non-hazardous Closed Oct 24, 2023
§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT WEST WALL AT PUBLIC HALL, 1st STORY
HPD ↗
B · Hazardous Closed Oct 24, 2023
§ 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSEHOLD ITEMS AT PUBLIC HALL, 1st STORY
HPD ↗
B · Hazardous Closed Oct 24, 2023
§ 27-2005 ADM CODE PROPERLY SECURE THE LOOSE THE WOOD TREAD ALL OF THEM FROM BOTTOM TO TOP AT PUBLIC HALL STAIRS, 4th STORY
HPD ↗
B · Hazardous Closed Oct 24, 2023
§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX 20 SQF AT WEST WALL AT PUBLIC HALL, 1st STORY ORIGINAL VIOLATION 163
HPD ↗
B · Hazardous Closed Sep 5, 2023
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOODEN FLOORS IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st STORY, 1st APARTMEN
HPD ↗
A · Non-hazardous Closed Sep 5, 2023
§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE WALLS AND CEILING IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st STO
HPD ↗
B · Hazardous Closed Sep 5, 2023
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st STOR
HPD ↗
B · Hazardous Closed Sep 5, 2023
§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING AND EAST AND SOUTH WALL IN THE BATHROOM LOCATED AT APT 1, 1st
HPD ↗
A · Non-hazardous Closed Sep 5, 2023
§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE WALLS AND CEILING IN THE BATHROOM LOCATED AT APT 1, 1st STORY, 1st
HPD ↗
C · Immediately hazardous Closed Sep 5, 2023
HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD ↗
C · Immediately hazardous Closed Sep 5, 2023
HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES AT PUBLIC HALL, 1st STORY
HPD ↗
B · Hazardous Closed Aug 29, 2023
§ 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING IN THE BATHROOM LOCATED AT APT 5R, 4th STORY, 2nd APARTMENT FROM EAST AT SOUTH
HPD ↗
C · Immediately hazardous Closed Aug 29, 2023
HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 5R, 4th STORY, 2nd APARTMENT FROM EAST AT SOUTH
HPD ↗
B · Hazardous Open Aug 29, 2023
§ 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION AT WASTE LINE AT SINK IN THE KITCHEN LOCATED AT APT 5R, 4th STORY, 2nd APARTMENT FROM EAST AT SOUTH
HPD ↗
B · Hazardous Closed Aug 29, 2023
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE BATHROOM LOCATED AT APT 5R, 4th STORY, 2nd
HPD ↗
B · Hazardous Closed Aug 29, 2023
HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF VERMIN WATERBUGS IN THE ENTIRE APARTMENT LOCATED AT APT 5R, 4th STORY, 2nd APARTMENT FROM EAST AT
HPD ↗
C · Immediately hazardous Closed Aug 29, 2023
§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE ..
HPD ↗
A · Non-hazardous Closed Aug 29, 2023
§ 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORM
HPD ↗
A · Non-hazardous Closed Aug 29, 2023
§ 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX BASEMENT STORY AT PUBLIC
HPD ↗
A · Non-hazardous Closed Aug 29, 2023
§ 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MU
HPD ↗
B · Hazardous Closed Aug 29, 2023
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT PLASTER AT CEILING AND NORTH WALL AT VESTIBULE AT PUBLIC HALL
HPD ↗
A · Non-hazardous Closed Aug 29, 2023
§ 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLL
HPD ↗
A · Non-hazardous Closed Aug 29, 2023
§ 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE B
HPD ↗
A · Non-hazardous Closed Aug 29, 2023
§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE BUZZER INTERCON FROM BUILDING VESTIBULE TO RETURN BUZZER AT FOYER AT APARTMENT 5R
HPD ↗
B · Hazardous Closed Aug 29, 2023
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR ALL WALLS AND CEILINGS IN THE ENTIRE APARTMENT LOCATED AT APT
HPD ↗
A · Non-hazardous Closed Aug 29, 2023
§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE BUZZER INTERCON FROM BUILDING VESTIBULE TO RETURN BUZZER IN THE FOYER LOCATED AT BSMT-APT 1, 1
HPD ↗
C · Immediately hazardous Closed Aug 29, 2023
§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LE
HPD ↗
C · Immediately hazardous Closed Aug 29, 2023
§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE AT
HPD ↗
A · Non-hazardous Closed Aug 9, 2023
§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX. 2 SQ. FT. AT NORTH WALL IN THE 1st ROOM FROM EAST AT NORTH LOCATED
HPD ↗
B · Hazardous Closed Aug 9, 2023
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT NORTH WALL IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT AP
HPD ↗
B · Hazardous Closed Aug 9, 2023
§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT NORTH WALL IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 2, 1st ST
HPD ↗
B · Hazardous Closed Aug 9, 2023
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT NORTH WALL IN VESTIBULE AT PUBLIC HALL AT BASEMENT
HPD ↗
A · Non-hazardous Closed Aug 9, 2023
§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT NORTH WALL IN VESTIBULE AT PUBLIC HALL AT BASEMENT
HPD ↗
B · Hazardous Closed Aug 9, 2023
§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT NORTH WALL IN VESTIBULE AT PUBLIC HALL AT BASEMENT
HPD ↗
A · Non-hazardous Closed Aug 9, 2023
§ 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MU
HPD ↗
A · Non-hazardous Closed Aug 9, 2023
§ 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX MISSING AT BASEMENT
HPD ↗
A · Non-hazardous Closed Aug 9, 2023
§ 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLL
HPD ↗
A · Non-hazardous Closed Aug 9, 2023
§ 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORM
HPD ↗
B · Hazardous Closed Aug 9, 2023
§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX. 2 SQ. FT. AT NORTH WALL IN THE 1st ROOM FROM EAST AT NORTH LOCATED
HPD ↗
B · Hazardous Closed Jul 27, 2023
§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE 11TH ,12TH 13TH AND 14TH WOOD THREAD FROM BOTTOM AT 5TH STORY PUBLIC HALL STAIRS AT PUBLIC HAL
HPD ↗
B · Hazardous Closed Jul 27, 2023
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDENT SHEETROCK AT THE NORTH WALL AT VESTIBULE AT PUBLIC HALL, 1st STO
HPD ↗
A · Non-hazardous Closed Jul 27, 2023
§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE NORTH WALL AT VESTIBULE AT PUBLIC HALL, 1st STORY
HPD ↗
A · Non-hazardous Closed Jul 27, 2023
§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT SOUTH WALL AT VESTIBULE AT PUBLIC HALL, 1st STORY
HPD ↗
B · Hazardous Closed Jul 27, 2023
§ 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF BICYCLES , SHOPPING CARTS AND BABY CARRIAGES AT PUBLIC HALL, 1st STORY
HPD ↗
A · Non-hazardous Closed Jul 27, 2023
§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE MAIL BOX LOCK AND KEY FOR APARTMENT 5F AT 5TH STORY AT PUBLIC HALL, 1st STORY
HPD ↗
B · Hazardous Closed Jul 27, 2023
§ 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSEHOLD ITEMS AT PUBLIC HALL, 4th STORY
HPD ↗
B · Hazardous Closed Jul 27, 2023
§ 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSEHOLD ITEMS AT PUBLIC HALL, 2nd STORY
HPD ↗
B · Hazardous Closed Jul 11, 2023
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETADANT MATRAIL FOR SOUTH WALL AT VESTIBULE AT PUBLIC HALL, 4th STORY
HPD ↗
B · Hazardous Closed Jul 11, 2023
§ 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSE HOLD ITEMS AT 1ST STORY PUBLIC HALL AT PUBLIC HALL, 4th STORY
HPD ↗
B · Hazardous Closed Jul 11, 2023
§ 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING SLIDE BALT AND EYE AT THE SCUTTEL AT PUBLIC HALL, 4th STORY
HPD ↗
B · Hazardous Closed Jul 11, 2023
§ 27-2005 ADM CODE PROPERLY SECURE THE LOOSE TREAD AT THE STAIRS FROM THE 3RD STORY TO THE 4TH STORY AT PUBLIC HALL STAIRS, 4th STORY
HPD ↗
C · Immediately hazardous Open Jul 8, 2023
HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 4, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD ↗
A · Non-hazardous Closed May 9, 2023
§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROXMATELY 20 SQUARE FEET AT NORTH WALL IN VESTIBULE AT BASEMENT
HPD ↗
A · Non-hazardous Closed May 9, 2023
§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT NORTH WALL IN VESTIBULE AT BASEMENT
HPD ↗
C · Immediately hazardous Closed May 9, 2023
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT NORTH WALL IN VESTIBULE AT BASEMENT
HPD ↗
C · Immediately hazardous Closed May 9, 2023
HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF RODENTS RATS ,BUILDING FRONT ENTRANCE COURT
HPD ↗
B · Hazardous Closed May 9, 2023
§ 27-2005 ADM CODE PROPERLY SECURE THE LOOSE WOOD TREAD 14TH FROM BOTTOM UP, AT PUBLIC HALL STAIRS, 3rd STORY
HPD ↗
C · Immediately hazardous Closed May 9, 2023
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE EDGE TRIM AT WOOD TREAD 4TH FROM BOTTOM UP, AT PUBLIC HALL STAIRS, 3rd STORY
HPD ↗
B · Hazardous Closed May 9, 2023
§ 27-2005 ADM CODE REPLACE WITH NEW THE MISSING COVER LIDS AT GARBAGE CANS AT BUILDING FRONT ENTRANCE COURT
HPD ↗
B · Hazardous Open May 9, 2023
§ 27-2005 ADM CODE PROPERLY SECURE THE LOOSE WOOD TREADS 1ST AND 2ND FROM BOTTOM UP, IN STARCASE AT CELLAR
HPD ↗
B · Hazardous Closed May 9, 2023
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING, IN BOILER ROOM AT CELLAR
HPD ↗
A · Non-hazardous Closed May 9, 2023
§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING, IN BOILER ROOM AT CELLAR
HPD ↗
C · Immediately hazardous Closed May 9, 2023
HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE AT CELLAR
HPD ↗
C · Immediately hazardous Closed May 9, 2023
HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES AT CELLAR
HPD ↗
B · Hazardous Closed May 9, 2023
§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROXMATELY 20 SQUARE FEET AT NORTH WALL IN VESTIBULE AT BASEMENT ORIGINAL
HPD ↗
B · Hazardous Open May 7, 2023
§ 27-2050 ADM CODE SEAL IN OPEN POSITION THE O.S.Y. VALVE OF THE SPRINKLER SYSTEM IN ACCORDANCE WITH THE RULES AND REGULATIONS OF THIS DEPARTMENT ...
HPD ↗
A · Non-hazardous Closed Apr 10, 2023
§ 27-2021 ADM CODE PROVIDE PLACE WITHIN THE BUILDING FOR THE STORAGE OF WASTE RECEPTACLES AND DISINFECT SAME REGULARLY.
HPD ↗
C · Immediately hazardous Closed Apr 10, 2023
HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES AT 1st BASEMENT FROM NORTH
HPD ↗
A · Non-hazardous Closed Apr 10, 2023
§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... MOLD ON INTERIOR NORTH WALL AT BUILDING ENTRANCE APPROX 24 SQFT AT 1st LOBB
HPD ↗
B · Hazardous Closed Apr 10, 2023
§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... MOLD ON INTERIOR NORTH WALL AT BUILDING ENTRANCE APPROX 24 SQFT AT 1st LOBB
HPD ↗
C · Immediately hazardous Closed Feb 28, 2023
§ 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT ENTRANCE DOOR TO BUILDING , AT BASEMENT AT PU
HPD ↗
B · Hazardous Closed Feb 28, 2023
§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT WEST WALL , BUILSING' VESTIBULE, AT BASEMENT AT PUBLIC HALL
HPD ↗
A · Non-hazardous Closed Feb 28, 2023
§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT ( APPROXIMATELY 1 SQFT) ,WEST WALL , BASEMENT STORY, AT PUBLIC HALL
HPD ↗
B · Hazardous Closed Feb 28, 2023
§ 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE CRACKED CERAMIC FLOOR TILES, AT BUILDING'S VESTIBULE, AT BASEMENT AT PUBLIC HALL
HPD ↗
B · Hazardous Closed Feb 28, 2023
§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT ( APPROXIMATELY 1 SQFT) ,WEST WALL , BASEMENT STORY, AT PUBLIC HALL ORIG
HPD ↗
C · Immediately hazardous Closed Feb 22, 2023
§ 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT ENTRANCE DOOR TO BUILDING AT PUBLIC HALL, 1st
HPD ↗
B · Hazardous Closed Feb 22, 2023
§ 27-2005 ADM CODE REPLACE WITH NEW THE MISSING ELECTRICAL OUTLET COVER, AT SOUTH WALL, AT PUBLIC HALL, 1st STORY
HPD ↗
C · Immediately hazardous Closed Oct 26, 2022
HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES AT PUBLIC HALL, 2nd STORY
HPD ↗
B · Hazardous Closed Oct 3, 2022
§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 4, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD ↗
C · Immediately hazardous Closed Oct 3, 2022
§ 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTI
HPD ↗
C · Immediately hazardous Closed Oct 3, 2022
HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 4, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD ↗
A · Non-hazardous Closed Oct 3, 2022
§ 27-2011 ADM CODE CLEANSE TO THE SATISFACTION OF THIS DEPARTMENT THE CERAMIC TILES SURFACE AND CAULKING OF VISIBLE MOLD AT SOUTH WALL AROUND BATHTUB IN THE BAT
HPD ↗
B · Hazardous Closed Oct 3, 2022
§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE INTERCOM SYSTEM FROM BASEMENT VESTIBULE TO SOUTH WALL PANEL IN THE FOYER LOCATED AT APT 4, 3rd STORY,
HPD ↗
C · Immediately hazardous Closed Oct 3, 2022
§ 27-2005, 2007 ADM CODE REMOVE DEVICE PREVENTING DOOR FROM BEING SELF-CLOSING HOOK AND LOOP DEVICES INSTALLED FLOOR TO VESTIBULE DOOR AT BASEMENT
HPD ↗
A · Non-hazardous Closed Oct 3, 2022
§ 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORM
HPD ↗
A · Non-hazardous Closed Oct 3, 2022
§ 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLL
HPD ↗
C · Immediately hazardous Open Oct 3, 2022
§ 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH
HPD ↗
C · Immediately hazardous Open Oct 3, 2022
§ 27-2056.7, 27-2056.8, 27-2056.9 ADM CODE -CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS DURING PERIOD OF UNIT VACANCY BY PERFORMING ACT
HPD ↗
B · Hazardous Closed Jun 24, 2022
§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE MAILBOX (APT 4) AT PUBLIC HALL, 1st STORY
HPD ↗
A · Non-hazardous Closed Jun 24, 2022
§ 27-2005 ADM CODE REFIT ENTRANCE DOOR AT PUBLIC HALL, 1st STORY
HPD ↗
C · Immediately hazardous Closed Jun 24, 2022
§ 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE .. AT PUBLIC HALL, 1st STORY
HPD ↗
B · Hazardous Open Jun 24, 2022
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 4, 4th ST
HPD ↗
B · Hazardous Closed Jun 24, 2022
§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT EAST WALL IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 4, 4th STO
HPD ↗
A · Non-hazardous Closed Jun 24, 2022
§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT WEST WALL, 1st WINDOW SASH FROM SOUTH AT WEST WALL IN THE KITCHEN LO
HPD ↗
B · Hazardous Closed Jun 24, 2022
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT WEST WALL IN THE KITCHEN LOCATED AT APT 4, 4th STORY, 1st A
HPD ↗
A · Non-hazardous Open Jun 24, 2022
§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT WEST WALL, 1st WINDOW SASH FROM SOUTH AT WEST WALL, 2nd WINDOW SASH
HPD ↗
B · Hazardous Open Jun 24, 2022
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT WEST WALL IN THE 3rd ROOM FROM EAST AT SOUTH LOCATED AT APT
HPD ↗
A · Non-hazardous Open Jun 24, 2022
§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES IN THE 1st ROOM FROM EAST AT SOUTH, THE 1st
HPD ↗
C · Immediately hazardous Open Jun 24, 2022
§ 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - U
HPD ↗
C · Immediately hazardous Open Jun 24, 2022
§ 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD-PAINT THAT IS XRF TESTED INCONCLUSIVE FOR LEAD CONTENT AT 0.5MG/CM2 AND IS PRESUMED LEAD PAINT AS SET
HPD ↗
C · Immediately hazardous Open Jun 24, 2022
§ 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - U
HPD ↗
C · Immediately hazardous Open Jun 24, 2022
§ 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD-PAINT THAT IS XRF TESTED INCONCLUSIVE FOR LEAD CONTENT AT 0.5MG/CM2 AND IS PRESUMED LEAD PAINT AS SET
HPD ↗
C · Immediately hazardous Closed Apr 20, 2022
HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 5F, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD ↗
B · Hazardous Closed Apr 20, 2022
§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 5F, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD ↗
B · Hazardous Closed Apr 20, 2022
§ 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER THE CEILING IN THE KITCHEN LOCATED AT APT 5F, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD ↗
B · Hazardous Closed Apr 20, 2022
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND WEST WALL IN THE KITCHEN LOCATED AT APT 5F, 4t
HPD ↗
B · Hazardous Closed Apr 20, 2022
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE SOUTH WALL IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT A
HPD ↗
B · Hazardous Closed Apr 20, 2022
§ 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF LADDER AT PUBLIC HALL, 1st STORY
HPD ↗
A · Non-hazardous Closed Apr 20, 2022
§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL CEILINGS AND ALL WALLS AT ALL STORIES AT PUBLIC HALL
HPD ↗
B · Hazardous Closed Apr 13, 2022
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING AND NORTH WALL AT VESTIBULE
HPD ↗
B · Hazardous Closed Apr 13, 2022
§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING TO NORTH WALL AT VESTIBULE
HPD ↗
A · Non-hazardous Closed Apr 13, 2022
§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING AND NORTH WALL AT VESTIBULE
HPD ↗
B · Hazardous Closed Apr 11, 2022
§ 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE FRONT YARD
HPD ↗
B · Hazardous Closed Apr 11, 2022
§ 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSEHOLD ARTICLES AND CONSTRUCTION MATERIALS AT PUBLIC HALL, 1st STORY
HPD ↗
B · Hazardous Closed Apr 9, 2022
§ 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF CONSTRUCTION MATERIALS AT PUBLIC HALL, 1st STORY
HPD ↗
A · Non-hazardous Closed Apr 9, 2022
§ 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MU
HPD ↗
A · Non-hazardous Closed Apr 9, 2022
§ 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE B
HPD ↗
A · Non-hazardous Closed Apr 9, 2022
§ 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORM
HPD ↗
C · Immediately hazardous Closed Apr 9, 2022
§ 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS
HPD ↗
B · Hazardous Closed Apr 9, 2022
§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE BELL/ BUZZER/INTERCOM SYSTEM AT PUBLIC HALL, 1st STORY
HPD ↗
B · Hazardous Closed Apr 9, 2022
§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR THAT IS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 5F, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD ↗
B · Hazardous Closed Apr 9, 2022
§ 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING AND WEST WALL IN THE KITCHEN LOCATED AT APT 5F, 5th STORY, 1st APARTMENT FROM EAST AT S
HPD ↗
A · Non-hazardous Closed Apr 9, 2022
§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING AND WEST WALL IN THE KITCHEN LOCATED AT APT 5F, 5th STORY,
HPD ↗
B · Hazardous Open Apr 9, 2022
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE WEST WALL IN THE 3rd ROOM FROM EAST AT SOUTH LOCATED AT AP
HPD ↗
A · Non-hazardous Open Apr 9, 2022
§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE 2nd WINDOW SASH FROM SOUTH AT WEST WALL IN THE 3rd ROOM FROM EAST A
HPD ↗
A · Non-hazardous Closed Apr 9, 2022
§ 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION THE 1st RADIATOR FROM SOUTH AT WEST WALL IN THE 3rd ROOM FROM EAST AT SOUTH LOCATED AT APT 4,
HPD ↗
A · Non-hazardous Closed Apr 9, 2022
§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE 1st WINDOW SASH FROM NORTH AT EAST WALL, 1st CLOSET FROM SOUTH AT W
HPD ↗
B · Hazardous Open Apr 9, 2022
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE WEST WALL IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT AP
HPD ↗
A · Non-hazardous Closed Apr 9, 2022
§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE 1st WINDOW SASH FROM SOUTH AT WEST WALL, 1st DOOR FRAME FROM EAST A
HPD ↗
B · Hazardous Closed Apr 9, 2022
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE 1st CLOSET FROM NORTH AT EAST WALL WALL IN THE KITCHEN LOC
HPD ↗
B · Hazardous Closed Apr 9, 2022
§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE BELL/BUZZER/INTERCOM SYSTEM IN THE ENTIRE APARTMENT LOCATED AT APT 4, 3rd STORY, 1st APARTMENT FROM E
HPD ↗
C · Immediately hazardous Closed Apr 9, 2022
HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 4, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD ↗
C · Immediately hazardous Open Apr 9, 2022
HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 4, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD ↗
C · Immediately hazardous Closed Apr 9, 2022
§ 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTI
HPD ↗
B · Hazardous Closed Apr 9, 2022
§ 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF SEVERAL PAINT CANS, BUILDING MATERIAL AND OTHER HOUSEHOLE ITEMS AT PUBLIC HALL, 1st STORY
HPD ↗
A · Non-hazardous Closed Apr 9, 2022
§ 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE B
HPD ↗
C · Immediately hazardous Closed Apr 9, 2022
§ 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS
HPD ↗
A · Non-hazardous Closed Apr 9, 2022
§ 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX MISSING AT PUBLIC HALL,
HPD ↗
A · Non-hazardous Closed Apr 9, 2022
§ 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MU
HPD ↗
A · Non-hazardous Closed Apr 9, 2022
§ 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORM
HPD ↗
A · Non-hazardous Closed Apr 9, 2022
§ 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLL
HPD ↗
C · Immediately hazardous Open Apr 9, 2022
§ 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - U
HPD ↗
C · Immediately hazardous Open Apr 9, 2022
§ 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - U
HPD ↗
C · Immediately hazardous Open Apr 9, 2022
§ 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - U
HPD ↗
A · Non-hazardous Open Apr 9, 2022
§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES IN THE 1st ROOM FROM EAST AT NORTH, THE BATH
HPD ↗
C · Immediately hazardous Open Apr 9, 2022
§ 27-2056.7, 27-2056.8, 27-2056.9 ADM CODE -CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS DURING PERIOD OF UNIT VACANCY BY PERFORMING ACT
HPD ↗
A · Non-hazardous Closed Feb 23, 2022
(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.G
HPD ↗
B · Hazardous Closed Jun 21, 2021
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL CEILING AT PUBLIC HALL, 4th STORY
HPD ↗
A · Non-hazardous Closed Jun 21, 2021
§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING AT PUBLIC HALL, 4th STORY
HPD ↗
A · Non-hazardous Closed Jun 21, 2021
§ 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLL
HPD ↗
A · Non-hazardous Closed Jun 21, 2021
§ 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MU
HPD ↗
A · Non-hazardous Closed Jun 21, 2021
§ 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORM
HPD ↗
A · Non-hazardous Closed Jun 21, 2021
§ 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE B
HPD ↗
A · Non-hazardous Closed Apr 7, 2021
(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.G
HPD ↗
I · Order to correct Closed Apr 7, 2021
§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PEN
HPD ↗
I · Order to correct Closed Oct 29, 2019
§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PEN
HPD ↗
I · Order to correct Closed Oct 16, 2018
§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PEN
HPD ↗
I · Order to correct Closed Nov 4, 2016
§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PEN
HPD ↗
I · Order to correct Closed Oct 8, 2015
§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PEN
HPD ↗
B · Hazardous Closed Sep 8, 2008
§ 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... AT CEILING & SOUTH WALL (APPRX. 5 SQ. FT.) (BASEMENT APT) IN THE BATHROO
HPD ↗
B · Hazardous Closed Sep 8, 2008
§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF EVIDENCE OF CONCEALED WATER LEAKS AT CEILING (BASEMENT APT) IN THE BATHROOM LOCATED AT APT 1,
HPD ↗
B · Hazardous Closed Sep 8, 2008
§ 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE CEILING & ALL WALLS (BASEMENT APT) IN THE BATHROOM LOCATED AT APT 1, 1st APARTMENT FROM EAST AT SOUT
HPD ↗
B · Hazardous Closed Sep 8, 2008
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE ENTIRE APARTMENT LOCATED AT BSMT-APT 1, 1st BSMT-APT FROM EAS
HPD ↗
B · Hazardous Closed Sep 8, 2008
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL TILE FLOOR IN THE ENTIRE APARTMENT LOCATED AT BSMT-APT 1, 1st BSMT-APT FR
HPD ↗
B · Hazardous Closed Sep 8, 2008
§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT BSMT-APT 1, 1st BSMT-APT FROM EAST AT SOUTH
HPD ↗
Deed & identifiers
SBL3019150051
SWIS610100
Parcel ID6101003019150051

Who owns 262 Clinton Avenue?

262 Clinton Avenue, Brooklyn is owned by Johnson, Cameron per the 2025 NYS assessment roll.
Public record, NYS tax roll 2025. Values are the assessor's, not an appraisal. Provided for informational purposes only — accuracy and completeness are not warranted or guaranteed; verify against official sources before relying on it. Disclaimer · Request redaction

Search by name or address · Browse all records